Element family · historical registry scope

HEX8 route coverage.

4 qualified bounded and 3 experimental combinations. A family name does not transfer qualification between analyses or material models.

HEX8 analysis routesSwipe, use the scrollbar or press ← / → while focused.
7 recorded combinations · source reviewed 2026-09-10 · Download source registry
ElementAnalysisRecorded statusScope details
HEX8Linear staticQualified bounded
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. Family-specific requalification is scheduled in G04.

Analysis formulation and scope →
Versioned source record ↗
HEX8ModalQualified bounded
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. G05 is PASS_WITH_LIMITATIONS: modal evidence covers eight internal family rows, while external correlation remains bounded and family-incomplete.

Analysis formulation and scope →
Versioned source record ↗
HEX8Newmark transientQualified bounded
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. G05 is PASS_WITH_LIMITATIONS: Newmark refinement and analytical evidence are complete, while external correlation remains bounded and family-incomplete.

Analysis formulation and scope →
Versioned source record ↗
HEX8HarmonicQualified bounded
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. G05 is PASS_WITH_LIMITATIONS: harmonic refinement and analytical evidence are complete, while external correlation remains bounded and family-incomplete.

Analysis formulation and scope →
Versioned source record ↗
HEX8Linear bucklingExperimental
Read limitations
HEX8 finite element geometryHEX8 schematic
  • EXPERIMENTAL does not mean QUALIFIED_BOUNDED, normal-use or production-ready.
  • No general Euler prediction or convergence claim is made; WP06/WP06B Euler and convergence FAIL records remain visible.
  • No certification, imperfections, nonlinear/post-buckling, plasticity, arbitrary-mesh, universal-accuracy, multi-mode or mixed-mesh claim.
  • No external correlation claim; current comparable Code_Aster/CalculiX evidence was unavailable.
  • HEX8R, SRI, B-bar and hourglass formulations are excluded.

Historical source note: G14 explicitly retains HEX8 buckling as more-evidence-required. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. No nonlinear collapse claim; 0.2.6 maturity extension is pending.

Analysis formulation and scope →
Versioned source record ↗
HEX8Nonlinear load controlExperimental
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. Maturity extension and multi-family correlation are scheduled separately.

Analysis formulation and scope →
Versioned source record ↗
HEX8Geometric nonlinear staticExperimental
Read limitations
HEX8 finite element geometryHEX8 schematic

Inherited evidence within the recorded scope; no new promotion is implied.

Historical source note: Combination state is inherited from aggregate 0.2.6 records; no new execution evidence is implied. G05 internal quantitative and analytical evidence is present; comparable independent external deck remains pending. Only bounded TET4/HEX8 Total-Lagrangian elasticity is qualified; high-order and finite-kinematic J2 remain non-qualified.

Analysis formulation and scope →
Versioned source record ↗

The versioned registry governs these combination statuses. Any linked Code_Aster case is a separate frozen linear static correlation, not qualification of every row.

Before you solve

Check orientation, geometry, loads, materials, the selected solver and required observables. Refinement does not repair an invalid Jacobian or establish an unsupported material route.